HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-36
1.9 Troubleshooting Guides
The following troubleshooting guides are intended to assist service technicians in quickly isolating
the probable causes of equipment malfunctions by following a logical, step-by-step process.
PROBLEM
PROBABLE CAUSES CORRECTIVE ACTION
Burner will not ignite.
Light in ON/OFF switch
is not illuminated.
A. ON/OFF switch is off. A. Turn ON/OFF switch on.
ON/OFF switch is on,
b
ut the switch light is not
illuminated.
A. No voltage at switch. A. Ensure line voltage is present at the
switch.
A. Drain microswitch circuit (filter-
equipped units) is open.
A. Ensure drain valve is fully closed and
microswitch is functioning. Replace
microswitch if defective.
B. Voltage is present at ON/OFF switch,
but continuity of the switch in ON
position is not "0.”
B. ON/OFF switch is defective. Replace
switch with a known working switch.
C. Continuity of thermostat is not "0"
(oil temperature is at least 15°F below
electronic thermostat setting).
C. Thermostat(s) is/are defective.
Replace defective thermostat with a
known working thermostat.
ON/OFF switch is on and
the switch light is
illuminated, but there is
no output to gas valve.
D. Gas valve is suspect. D. Go to "No burner flame" section.
Page view 40